Summary

TROUBLE SHOOTING,PREVENTIVE MAINTENANCE WORK,DAILY&MONTHLY MAINTENANCE REPORT,MONTHLY POWER CONSUMPTION REPORT,ETC

Experience

Company Logo
Electrical Maintenance Technician/Foreman
Saudi operation and maintenance company
Apr 2012 - Mar 2016 | Dammam, Saudi Arabia

PERFORMED PREVENTIVE MAINTENANCE WORK TO ALL ELECTRICAL EQUIPMENT
DIFFERENT TYPE CIRCUIT BREAKER 13.8KV,69KV. OIL AND SF6 BREAKERS
PERFORMED DAILY MAINTENANCE REPORTS
PERFORMED MONTHLY POWER CONSUMPTION REPORTS,ETC

Company Logo
Electrical Foreman
saudi services for electromechnic works co.ltd
Oct 2009 - Sep 2011 | Riyadh, Saudi Arabia

 I worked 13.8kv switch gear
 Termination and testing of the control panels of 380 kv sub station.
 Termination and testing of the relay panels of 13.8 kv switchgears..
 I have experience to use Freja and sevrker (AUX RELAY & MCB TESTING).
 I also familiar to the work related to Power Transformer,
 Work at the Paper machine 7 in Bulleh shah paper mill on,installation,erection, commissioning of electrical system
 Work at the Power house and sub station (2000 MW) in PP10 Saudi Arabia in Riyadh
 I have experience of work on the 132 KV grid station HT incoming and Out going panels and also SF6 breakers,
 H.T Transformers oil dehydration test.
Worked in power system and testing with ALFNAR CO.LTD
I have working experience of ABB (ACDB) and ABB (DCDB).
I also have working experience on the panels of Siemens made HT control Panels.
 I worked HT cable mager testing and high voltage testing.
 Installation fitting and commissioning of SF 6 circuit breaker.
 Ht switch gear SF6 switch gear circuit breaker mager and timing testing
 Also work on the operating panels of power distribution, in coming and out going HT panels.
Working in project Packages limited (Bulleh Shah Paper Mill Project) Kasur as SUPERVISOR.
Working at PP10 Riyadh K.S.A with Electro mechanic works.
I worked also FR panel and DSM panel modification.
I worked also CT primary injection and CT modification and VT loop testing.
I have work experience ILP(IN DOOR LIGHTING PANEL) panel OLP(OUT DOOR LIGHTING PANEL ) panel EILP(EMERGENCY INDOOR LIGHTING PANEL) modification and Termination.

Company Logo
Electrical Supervisor
Bulleh Shah Paper Mill Project
Feb 2006 - Mar 2009 | Kasur, Pakistan

Designing low voltage panels as per street over head crane drawing.
Trouble shooting for electrical circuit,
Performed preventive maintenance work of electrical equipment.
Coordinate with engineer and seniors during work.

Education

Punjab Board of Technical Education Lahore
Diploma, Electrical‎
Electric Power and Control System, Electrical
Completed