خلاصہ

I'm a Pakistan national, have done with graduation in "Mechanical Engineering B.E" from NED UET.

I have demonstrated history of working in the field of HVAC Design MEP, Plant Maintenance, Manufacturing and packages.

All my working career has been with companies like PAC Kamra, Artistic Milliners, KMNR Engineering Pvt limited and Kompass Pakistan.

I am eager to serve in an organization that enables me to transform my theoretical knowledge into practical implementation

پراجیکٹس

Synthesis and fabrication of Al/graphite/CF MMC

تجربہ

کمپنی کا لوگو
Process Engineer
Kompass Pakistan
اگست ۲۰۲۰ - موجودہ | Karachi, Pakistan


Started as Trainee Engineer at Kompass Pakistan. 
Responsible for implementing 5s and HRM, achieving daily production targets.
Worked on small projects under production department with required QC and safety trainings.

کمپنی کا لوگو
Design Engineer
KMNR Engieering
اکتوبر ۲۰۱۹ - جولائی ۲۰۲۰ | Karachi, Pakistan


-Providing design services for HVAC, educational and health care institutions.
-Specialize in designing building systems to North American codes and standards.
-Familiar with psychrometric charts, HVAC piping and duct sizing, parking ventilation.
-Ashrae standards, cooling heating load calculations, occupnacy, equipment load, floor slab perimeter, VFC summary sheet,Chilled and hot water Riser diagrams, Condensate drain pipe sizing, Roof drain.
-Heating and Cooling load calcs using Elite CHVAC.
PROJECTS
-Load calculation of 5610 Roblin Blvd Winnipeg Manitoba Multi Family Building. 
-Load calculation of 65 King Street East Toronto Ontario, Office fit up.
-Load calculation of 151 Yonge Street Replace Chillers CH-1 & CH-2.
-Load calculation of Ste 143 Dental Office Fit up- 3280 Blood.
-Zoning Drawing and CHVAC- 4700 Keele Street Toronto Ontario LL Aviva Centre Tennis Stadium.
-Load calcs of 412 Sparks Street Ottawa Ontario Ottawa Retirement Residence by Signature.
-Load calcs of 8731 Spires Road Richmond British Columbia Fit up Townhome Units.
-Zoning Drawing and CHVAC of 445 Wes Graham Way Waterloo Ontario O2
-Heating and Cooling load calcs of 1201 Larry Uteck, Bedford, N.S.
-Heating/Cooling load of 2358 McPhillips St Winnipeg Manitoba Unit 4 Doctors Office.
-Heating/Cooling load calcs of 1531 Pembina Hwy Winnipeg Manitoba Dentist Clinic Fit-up.
-Heating and Cooling load calcs for Herring Cove Halifax Nova Scotia / Suite apartment
-Heating/Cooling load calcs and Ashrae 6.2 calculations of Salmon Avenue Bracebridge Ontario Base Building.
-Duct Designing, Rooting of Broadway Avenue, Toronto, Ontario - Tender Design.
-Heating and Cooling load calcs of 1132 Portage Ave Winnipeg Manitoba Cilantro's Restaurant.
-Heating and Cooling load calcs of 36 Robinson Ave.
-Heating/Cooling load calcs of Universite de I'Ontario Francais Fit Out, Toronto Ontario.
-Elite Load Calcs of 2095 Matheson Blvd Mississauga Ontario Pepsi Co Regional HO Fit Up Building A & B.

کمپنی کا لوگو
Internee Engineer
PAC Kamra
اپریل ۲۰۱۸ - مئی ۲۰۱۸ | Karachi, Pakistan

I have good management skills with challenging qualities.

تعلیم

NED University of Engineering and Technology Karachi
بیچلرز, BSc, ‎
Mechanical
CGPA 3.7/4
2019

پیشہ ورانہ مہارتیں

ماہر 3D Design
متوسط Analytical Skills
ماہر Blue Beam
ابتدائی Data Processing
ماہر Drafting Blueprints
متوسط Elite Webview
متوسط MATLAB Command
ماہر Numerical Analysis
ماہر Solidworks Or Similar Software
ماہر Strong Mathematical Knowledge
متوسط رسم الآلات

زبانیں

ماہر انگریزی

آپ کن کمپنیز کی پیروی کر رہے ہیں